Uttar Pradesh Lighting Energy Efficiency Project (ULEEP) in Circles I & II of Varanasi, Zone, UttarPradesh, India
[]
Host party(ies) India
Methodology(ies) AMS-II.J. ver. 3
Standardised Baselines N/A
Estimated annual reductions* 19,589
Start date of first crediting period. 01 Sep 09
Length of first crediting period. 7 years
DOE/AE DNV-CUK
Period for comments 07 Jul 09 - 05 Aug 09
The operational/applicant entity working on this project has decided to make the Project Design Document (PDD) publicly available directly on the UNFCCC CDM website.
PDD PDD (1427 KB)
Local stakeholder consultation report: N/A
Impact assessment summary: N/A
Submission of comments to the DOE/AE Compilation of submitted inputs:
Project participant should write in PDD how result of survey would be responsible for reduction of broken CFL in the crediting year. How to ensure that selection of sample households were random is not describe in PDD. How the survey result calculate smaller emission reduction in crediting year is not describe in PDD. It is also possible that project participants would give good CFL in the household for survey and replace their CFL immediately after breaking and show that in a small sample no or less CFL breaks, when in reality a lot of CFL breaks in the rest of the project range. This will be a lie and inflate emission reductions unethically.
Submitted by: Ethical Emission Reductions

CFL-hour operation per year data. is not clear whether 3.5 hours is fixed or estimated. How will the project participants to ensure that they will not influence the households in the survey to use CFL for the more number of hours and then inflate emission reductions unethical. This should be set at only 3.5 hours and fix it for the credting year.
Submitted by: Ethical Emission Reductions

How to ensure that higher value CFL 100W not be distributed only to inflate emission reductions unethically. Project participant to describe in the pdd
Submitted by: Ethical Emission Reductions


The comment period is over.
* Emission reductions in metric tonnes of CO2 equivalent per annum that are based on the estimates provided by the project participants in unvalidated PDDs