22:55 07 Jul 25
Registration Request for Review Form
CDM project activity/programme of activities registration request review form (CDM-REGR-FORM) (Version 03.0) |
---|
Reference number of the proposed CDM project activity/programme of activities (PoA) submitted for registration | 5506 |
---|---|
Title of the proposed CDM project activity/PoA submitted for registration | PT Dalle Energy Batam CCGT conversion project, Indonesia |
Please indicate, in accordance with paragraphs 37 and 40 of the CDM modalities and procedures, which validation requirement(s) may require review. A list of requirements is provided below. Please provide reasons in support of the request for review. Including any supporting documentation. | |
The following are requirements derived from paragraph 37 of the CDM modalities and procedures: | |
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
|
The following are requirements derived from paragraph 40 of the CDM modalities and procedures: | |
![]() ![]() ![]() ![]() ![]() ![]() |
|
![]() |
|
Additional information | |
1) The DOE is required to further substantiate the suitability of the O&M cost, in particular a) how the cost sourced from contracts/agreements in 2005, which appears to be for open cycle; is suitable for the maintenance cost for the project activity (i.e. conversion from open cycle to combined cycle comprising only the steam turbine unit), b) how "Service/rental charge by PT Mitra Energi Batam (MEB)" is suitable for the project activity as this charge is for whole power plant and c) how "Management fee" is suitable as there is no explanation of this cost. Please refer to VVM v 1.2 paragraph 111. 2) The applied methodology states that parameter EGOC and EFHIST should be determined based on data from the operation of power plant in open cycle mode based on five years of generation records at the time of validation (MWh). If five years data is not available, then data for the highest number of complete years available should be used, with a minimum of three full years. Further clarification is required how the DOE validates EGOC and EFHIST as per the applied methodology as the PDD (p 48) indicates that two-year actual data ( April 2006 - March 2008) and one year estimated data based on the total net capacity of the plant by a capacity factor and the number of hours in one year are used for parameter EGOC and EFHIST. Please refer to ACM0007 Ver.04 (p 5). |
|
Date | 26 Feb 12 |