Project title of the project activity or programme of activities (PoA) for which issuance is requestedFrio Industrias Argentinas S.A (“FIASA”) Hydro-fluorocarbon 23 (“HFC23”) Capture, Storage and Decomposition Project (0807)
DOE that requested for issuance and date of requestTÜV SÜD (29 Apr 12)
Please indicate, in accordance with paragraphs 65 of the CDM modalities and procedures, for which reason(s) you request review
Incompetence
Please indicate reasons for the request for review
1) The DOE explains on page 20 of the verification report that the CLA0191 has not been taken into account in the verification. However, it provides additional information which is not part of the formal verification. CLA0191 should be fully considered in the verification process.

2) According to the PDD the two production lines started operation in 1993 and 1997. This does not fully match with the dates of the certificates provided in the verification report. Please clarify when each of the production lines started commercial operation and why the registration certificates are from 2002 if the plant started operation earlier.
Date 15 Oct 12