15:54 22 Dec 24
AMS-II.G.:
Energy efficiency measures in thermal applications of non-renewable biomass --- Version 13.1
Submit comments for improvement of this methodology (please login)
Title |
Energy efficiency measures in thermal applications of non-renewable biomass (565 KB)
Word version (194 KB)
Tools referenced in this methodology:
Default values for common parameters (185 KB)
|
||
---|---|---|---|
Version number |
|
||
Scale | Small scale | ||
Type | II | ||
Status | Active | ||
Validity | Valid from 08 Sep 22 onwards | ||
Sectoral scope(s) | 3 | ||
Clarifications/Revisions* | Clarification on the use of wood fuel emission factor under AMS-II.G. (submitted 21 Feb 23): SSC_836 (146 KB) | ||
Clarification on the terminal efficiency of a charcoal-based project device under AMS-II.G. (submitted 19 Jan 24): SSC_842 (127 KB) | |||
Previous Versions | |||
Title | Energy efficiency measures in thermal applications of non-renewable biomass (575 KB) | ||
Version number | 12.0 | ||
Validity |
Valid from 14 Dec 20 to 07 Sep 22
Requests for registration can be submitted until 05 May 2023 23:59:59 GMT |
||
Sectoral scope(s) | 3 | ||
Title | Energy efficiency measures in thermal applications of non-renewable biomass (543 KB) | ||
Version number | 11.1 | ||
Validity |
Valid from 28 Nov 19 to 13 Dec 20
Requests for registration can be submitted until 10 Aug 2021 23:59:59 GMT |
||
Sectoral scope(s) | 3 | ||
Clarifications/Revisions* | Clarification on non-renewable biomass in AMS-II.G. (submitted 27 Dec 19): SSC_770 (118 KB) | ||
Clarification on the validity and applicability of monitoring survey results under AMS-II.G. (submitted 06 Apr 20): SSC_781 (227 KB) | |||
Clarification on multiple separate monitoring reports for PoAs applying AMS-II.G. (submitted 05 Jun 20): SSC_787 (111 KB) | |||
Clarification regarding AMS-II.G. para 38 on the life span of stoves and the default replacement of devices after the end of their life span (submitted 08 Sep 20): SSC_796 (127 KB) | |||
Title | Energy efficiency measures in thermal applications of non-renewable biomass (605 KB) | ||
Version number | 10.0 | ||
Validity |
Valid from 31 Aug 18 to 27 Nov 19
Requests for registration can be submitted until 24 Jul 2020 23:59:59 GMT |
||
Sectoral scope(s) | 3 | ||
Clarifications/Revisions* | Clarification on batch definition and commissioning date of batch under AMS-II.G. (submitted 11 Jul 19): SSC_759 (242 KB) | ||
Inclusion of solar electric cookers as a new technology/measure in a PoA applying AMS-I.E and AMS-II.G, and currently distributing improved biomass cookstoves (submitted 27 Jan 20): SSC_773 (101 KB) | |||
Clarification on multiple separate monitoring reports for PoAs applying AMS-II.G. (submitted 05 Jun 20): SSC_787 (111 KB) | |||
Clarification on the default schedule of linear decrease in efficiency under AMS-II.G. (submitted 25 Jun 20): SSC_789 (134 KB) | |||
Title | Energy efficiency measures in thermal applications of non-renewable biomass (598 KB) | ||
Version number | 9.0 | ||
Validity |
Valid from 01 Nov 17 to 30 Aug 18
Requests for registration can be submitted until 27 Apr 2019 23:59:59 GMT |
||
Sectoral scope(s) | 3 | ||
Clarifications/Revisions* | Clarification on applicability of paragraph 41 of AMS-II.G ver 09.0 (submitted 05 Jan 18): SSC_732 (147 KB) | ||
Clarification on applicability of paragraph 41 of AMS-II.G version 09.0 to small-scale CDM project activities (submitted 21 Apr 18): SSC_735 (364 KB) | |||
Clarification on the method to determine the quantity of woody biomass through surveys under AMS-II.G. (submitted 10 Jun 18): SSC_738 (265 KB) | |||
Clarification request on renewal of the fNRB value (submitted 20 Jul 18): SSC_741 (103 KB) | |||
Clarification on the units used in the fNRB calculation under Tool30 (submitted 31 Jul 18): SSC_742 (217 KB) | |||
Clarification on eligible guidelines to measure the efficiency of the project device in AMS-II.G. (submitted 01 May 19): SSC_754 (145 KB) | |||
Title | Energy efficiency measures in thermal applications of non-renewable biomass (569 KB) | ||
Version number | 8.0 | ||
Validity |
Valid from 22 Jul 16 to 31 Oct 17
Requests for registration can be submitted until 28 Jun 2018 23:59:59 GMT |
||
Sectoral scope(s) | 3 | ||
Clarifications/Revisions* | Clarification on monitoring requirements under AMS-II.G (submitted 21 Sep 16): SSC_724 (123 KB) | ||
Clarification on efficiency testing for institutional improved cookstoves of different saucepan capacities under AMS-II.G (submitted 26 Oct 16): SSC_725 (112 KB) | |||
Clarification on the requirements to use simplified approach to test stove efficiency under AMS-II.G (submitted 06 Nov 16): SSC_726 (105 KB) | |||
Clarification on the test method to demonstrate above 20% stove efficiency under AMS-II.G (submitted 18 Nov 16): SSC_727 (110 KB) | |||
Clarification on ICS lifespan and definition of historical data as mentioned AMS-II.G ver 08 (submitted 19 Jan 18): SSC_733 (222 KB) | |||
Clarification on applicable emission factor under AMS-II.G. (submitted 04 Apr 18): SSC_734 (213 KB) | |||
Clarification on the method to determine fNRB values under AMS-II.G. (submitted 18 Jun 18): SSC_739 (106 KB) | |||
Clarification on Water Boiling Test (WBT) under AMS-II.G. (submitted 03 Apr 19): SSC_752 (142 KB) | |||
Calibration standard for equipment in AMS-II.G. (submitted 22 Apr 19): SSC_753 (284 KB) | |||
Clarification on the use of the lower bound approach to determine efficiency drops under AMS-II.G. (submitted 20 Jan 21): SSC_804 (120 KB) | |||
Title | Energy efficiency measures in thermal applications of non-renewable biomass (538 KB) | ||
Version number | 7.0 | ||
Validity |
Valid from 24 Jul 15 to 21 Jul 16
Requests for registration can be submitted until 19 Mar 2017 23:59:59 GMT |
||
Sectoral scope(s) | 3 | ||
Title | Energy efficiency measures in thermal applications of non-renewable biomass (490 KB) | ||
Version number | 6.0 | ||
Validity |
Valid from 21 Feb 14 to 23 Jul 15
Requests for registration can be submitted until 19 Mar 2016 23:59:59 GMT |
||
Sectoral scope(s) | 3 | ||
Clarifications/Revisions* | Clarification on the requirement to monitor continued use of baseline stoves under AMS-II.G (submitted 06 Aug 14): SSC_711 (219 KB) | ||
Clarification on the monitoring requirements for usage days of project devices and baseline stoves under AMS-II.G (submitted 23 Sep 14): SSC_713 (150 KB) | |||
Clarification on monitoring of the number of utilization days for the project device under AMS-II.G. (submitted 09 Jun 20): SSC_786 (92 KB) | |||
Title | Energy efficiency measures in thermal applications of non-renewable biomass (182 KB) | ||
Version number | 5.0 | ||
Validity |
Valid from 07 Dec 12 to 20 Feb 14
Requests for registration can be submitted until 18 Oct 2014 23:59:59 GMT |
||
Sectoral scope(s) | 3 | ||
Clarifications/Revisions* | Revision of calculations to include multiple types of cook stoves under AMS-II.G (submitted 21 Feb 13): SSC_671 (158 KB) | ||
Clarification on the use of qualitative surveys to determine the amount of woody biomass under AMS II.G (submitted 11 Jan 13): SSC_674 (117 KB) | |||
Revision of AMS-II.G concerning sample size requirements for thermal efficiency testing (submitted 25 Apr 13): SSC_684 (86 KB) | |||
Clarification on thermal efficiency monitoring requirements under AMS-II.G (versions 3.0, 4.0 and 5.0) (submitted 21 Aug 13): SSC_695 (85 KB) | |||
Clarification on the use of default values from the latest version of the methodology AMS-II.G (submitted 23 Jan 15): SSC_717 (97 KB) | |||
Validity of the results of the annually made monitoring surveys like Kitchen Performance Test (KPT) (submitted 26 Sep 18): SSC_743 (211 KB) | |||
Title | Energy efficiency measures in thermal applications of non-renewable biomass (248 KB) | ||
Version number | 4.0 | ||
Validity |
Valid from 03 Aug 12 to 06 Dec 12
Requests for registration can be submitted until 07 Aug 2013 23:59:59 GMT |
||
Sectoral scope(s) | 3 | ||
Clarifications/Revisions* | Clarification on ex-post monitoring of efficiency of improved cookstoves in AMS-II.G (submitted 11 Sep 12): SSC_659 (135 KB) | ||
Clarification on thermal efficiency monitoring requirements under AMS-II.G (versions 3.0, 4.0 and 5.0) (submitted 21 Aug 13): SSC_695 (85 KB) | |||
Clarification on the management of cookstove numbers in a CPA under AMS-II.G (submitted 14 Jan 16): SSC_720 (115 KB) | |||
Title | Energy efficiency measures in thermal applications of non-renewable biomass (248 KB) | ||
Version number | 3.0 | ||
Validity |
Valid from 29 Apr 11 to 02 Aug 12
Requests for registration can be submitted until 03 Apr 2013 23:59:59 GMT |
||
Sectoral scope(s) | 3 | ||
Clarifications/Revisions* | Clarification on the determination of fNRB in AMS-II.G (submitted 27 Jun 11): SSC_545 (205 KB) | ||
Clarification on monitoring requirements for stove efficiency for a project activity utilizing Kitchen Performance Test (submitted 08 Sep 11): SSC_566 (210 KB) | |||
Clarification on energy efficiency requirements for project cookstoves under AMS-II.G (submitted 12 Dec 11): SSC_595 (254 KB) | |||
Clarification on the combined use of AMS-I.E and AMS-II.G depending on renewable biomass availability (submitted 10 Apr 12): SSC_624 (175 KB) | |||
Clarification on the applicability of AMS-II.G to a project involving efficient brick production and displacement of non-renewable biomass (submitted 08 May 12): SSC_637 (164 KB) | |||
Revision of AMS-II.G to include monitoring requirements for replaced project technologies (submitted 27 Jul 12): SSC_654 (150 KB) | |||
Clarification on how to deal with differences in efficiency test under AMS-II.G (submitted 06 Sep 12): SSC_660 (133 KB) | |||
Clarification on thermal efficiency monitoring requirements under AMS-II.G (versions 3.0, 4.0 and 5.0) (submitted 21 Aug 13): SSC_695 (85 KB) | |||
Clarification on the requirement to avoid double counting under AMS-II.G (submitted 07 Mar 14): SSC_703 (155 KB) | |||
Eligibility of an induction cookstove model that is powered by the user’s solar generated electricity (submitted 11 Jul 19): SSC_756 (188 KB) | |||
Clarification on efficiency testing of a stove model made by several manufacturers under AMS-II.G. (submitted 11 Jul 19): SSC_760 (154 KB) | |||
End-of-life replacement of existing cookstoves (ICS) in AMS-II.G. (submitted 10 Sep 19): SSC_764 (268 KB) | |||
Inclusion of solar electric cookers as a new technology/measure in a PoA applying AMS-I.E and AMS-II.G, and currently distributing improved biomass cookstoves (submitted 27 Jan 20): SSC_773 (101 KB) | |||
Title | Energy Efficiency Measures in Thermal Applications of Non-Renewable Biomass (262 KB) | ||
Version number | 2.0 | ||
Validity |
Valid from 18 Dec 09 to 28 Apr 11
Requests for registration can be submitted until 29 Dec 2011 23:59:59 GMT |
||
Sectoral scope(s) | 3 | ||
Clarifications/Revisions* | Clarification on the determination of biomass savings in AMS-II.G (submitted 19 Mar 10): SSC_395 (252 KB) | ||
Title | Energy Efficiency Measures in Thermal Applications of Non-Renewable Biomass (189 KB) | ||
Version number | 1.0 | ||
Validity |
Valid from 01 Feb 08 to 17 Dec 09
Requests for registration can be submitted until 17 Aug 2010 23:59:59 GMT |
||
Sectoral scope(s) | 3 | ||
Clarifications/Revisions* | Clarifications regarding the use of grid in the baseline scenario (submitted 27 Jul 08): SSC_202 (145 KB) | ||
Clarification about the threshold of thermal energy savings in AMS-II.G (submitted 21 Sep 08): SSC_233 (158 KB) | |||
Clarification on end-user information in cookstove sales/distribution records under AMS-I.E and AMS-II.G (submitted 17 Dec 18): SSC_746 (147 KB) |
* Only the requests for clarification and revision that have been clarified by the SSC WG are displayed. To view all requests for clarification, go to this page. To view all requests for revision, go to this page.
Offset now: visit the United Nations Carbon Offset Platform
Connect with us: