The DOE is requested to verify the justification of the data used for the ex-ante emission reduction calculations as per VVS version 2 paragraphs 98, 99 and 100.
The DOE shall further clarify how it has determined that the efficiency of the baseline cogeneration unit for the greenfield project is in line with the requirement of para 29 of the applied methodology AMS.I.C version 19. In particular, the DOE is requested to further explain the appropriateness of the efficiency of the baseline cogeneration unit as 82%, considering the reference from only one manufacturer of such equipment (letter from the boiler manufacturer dated 12/04/2012).
The DOE is requested to verify the justification of the data used for the ex-ante emission reduction calculations as per VVS version 2 paragraphs 98, 99 and 100.
The DOE shall further clarify how it has determined that the efficiency of the baseline cogeneration unit for the greenfield project is in line with the requirement of para 29 of the applied methodology AMS.I.C version 19. In particular, the DOE is requested to further explain the appropriateness of the efficiency of the baseline cogeneration unit as 82%, considering the reference from only one manufacturer of such equipment (letter from the boiler manufacturer dated 12/04/2012).