Info Report Check
Submission incomplete:
1: The DOE is requested to describe all the assumptions/ data/references listed in the PDD for the baseline identification as per VVM v1.2 paragraph 87 (a).
The selection of the baseline fuel for the heat generation component is "bunker fuel oil", however the DOE did not include information on why this fossil fuel and not other fossil fuel has been selected.

2: The DOE is requested to include information on how it has validated the input values to the financial calculations as per VVM v 1.2 paragraph 114 (a).
The DOE did not provide information on why only the portion of heat and electricity generated from biogas is considered in the investment analysis, while the saving costs are associated with the total amount of heat and electricity generated from the proposed project activity.

3: The DOE is requested to identify if the PDD has been updated and rectified according to the responses to the CARs, CLs and or FARs raised during validation as per VVM v 1.2 paragraph 39.
Closure of CL13 bullet 5 states: "The parameter EFCO2,ff,boiler has been removed from project documentation as it had no relevance for ER calculation. The section in the PDD has been revised accordingly." However this parameter is included in the emission reductions calculation in the PDD. Please clarify.