1: The DOE is requested to include information on how it has validated the suitability of input values at the time of investment decision, as per VVM v 1.2 paragraph 114 (a) and EB 62 Annex 5, paragraph 6.
In particular, the DOE is requested to provide information on how it validated:

(i) the suitability of the applied nodal tariff. In doing this, the DOE is requested to confirm that the applied tariff was the latest available tariff by the CNE at the time of investment decision and to confirm how the time of investment decision was validated. Please, provide a valid link to the CNE report referred.

(ii) the conversion rates from Chilean pesos to US Dollars and from Euros to US Dollars at the time of investment decision;

(iii) the debt/equity ration and that no debt was used in the investment.

The DOE is also requested to explain how it validated that the input values were valid and applicable to the proposed project activity at the time of investment decision. In particular, the total investment and the "other costs" (i.e. land rent, administration, power from the grid and Miscellaneous costs), given that the DOE has not justified why the referred evidences from Europe are applicable for the host country.

2: The DOE is requested to describe the steps undertaken to assess if the monitoring arrangements are feasible to be implemented within the project design as per VVM v1.2 paragraph 124(b).
The PP/DOE are requested to specify the calibration frequency and the applicable local grid standards for calibration of electricity meters.