23:05 11 Dec 24
Info Report Check
Submission incomplete:
1: PoA-DD has this info on crediting period.
"SECTION J. Crediting period type and duration
>>
Renewable crediting period
21 Years 00 months"
It does not indicate the that the next PoA period commences on the day immediately after the expiration of the current PoA period.
2: Validation report has several inconsistencies
1. Validation report mentions on page 3 that "Applus+ Certification performed interviews, telephone conferences, and physical site inspection with project stakeholders to confirm selected information and to resolve issues identified in the document review". However, on page 6 it is mentioned that "... since the emission reduction estimated is less than 100,000 tCO2eq , assessment team
didn’t conducted site visit for ... "
2. Validation report mentions that "Once the project is made available for the global stakeholder consultation process, the members of the assessment team carried out ...". However, as per the CDM project cycle procedure for programmes of activities (version 02.0), the renewal of PoA period is not subject to global stakeholder consultation process.
3. At various places in the Validation Report, the DOE refers to the programme of activity and the design document as "the project" and "the project design documentation". To distinguish from stand alone CDM project activity, kindly please align the wording to "programme of activity" and "PoA-DD".
4. Validation report includes "The Sample estimation emission reduction for the renewal crediting period". However, the PoA-DD being validated does not have any CPA or sample estimation of emission reduction from a CPA.
5. PoA-DD has this info on crediting period. "SECTION J. Crediting period type and duration >> Renewable crediting period 21 Years 00 months".
It does not indicate the that the next PoA period commences on the day immediately after the expiration of the current PoA period. This has not been checked and reported in the validation report.
It is also noted that the validation report is uploaded with a file name "FVR-POA renewal-9419-final.pdf (264 KB)" whereas the correct reference for the PoA-DD is 9292.
3: Crediting period continuity not checked
PoA-DD has this info on crediting period. "SECTION J. Crediting period type and duration >> Renewable crediting period 21 Years 00 months". It does not indicate the that the next PoA period commences on the day immediately after the expiration of the current PoA period. This has not been checked and reported in the validation report
1: PoA-DD has this info on crediting period.
"SECTION J. Crediting period type and duration
>>
Renewable crediting period
21 Years 00 months"
It does not indicate the that the next PoA period commences on the day immediately after the expiration of the current PoA period.
2: Validation report has several inconsistencies
1. Validation report mentions on page 3 that "Applus+ Certification performed interviews, telephone conferences, and physical site inspection with project stakeholders to confirm selected information and to resolve issues identified in the document review". However, on page 6 it is mentioned that "... since the emission reduction estimated is less than 100,000 tCO2eq , assessment team
didn’t conducted site visit for ... "
2. Validation report mentions that "Once the project is made available for the global stakeholder consultation process, the members of the assessment team carried out ...". However, as per the CDM project cycle procedure for programmes of activities (version 02.0), the renewal of PoA period is not subject to global stakeholder consultation process.
3. At various places in the Validation Report, the DOE refers to the programme of activity and the design document as "the project" and "the project design documentation". To distinguish from stand alone CDM project activity, kindly please align the wording to "programme of activity" and "PoA-DD".
4. Validation report includes "The Sample estimation emission reduction for the renewal crediting period". However, the PoA-DD being validated does not have any CPA or sample estimation of emission reduction from a CPA.
5. PoA-DD has this info on crediting period. "SECTION J. Crediting period type and duration >> Renewable crediting period 21 Years 00 months".
It does not indicate the that the next PoA period commences on the day immediately after the expiration of the current PoA period. This has not been checked and reported in the validation report.
It is also noted that the validation report is uploaded with a file name "FVR-POA renewal-9419-final.pdf (264 KB)" whereas the correct reference for the PoA-DD is 9292.
3: Crediting period continuity not checked
PoA-DD has this info on crediting period. "SECTION J. Crediting period type and duration >> Renewable crediting period 21 Years 00 months". It does not indicate the that the next PoA period commences on the day immediately after the expiration of the current PoA period. This has not been checked and reported in the validation report
Offset now: visit the United Nations Carbon Offset Platform
Connect with us: