Info Report Check
Submission incomplete:
The monitoring report shall contain, for each of the CPAs covered by the monitoring report, the formula used for, and the calculations of, the baseline emissions/baseline net removals, project emissions/actual net removals, leakage emissions (if any), and emission reductions or net anthropogenic removals.
The calculation and results of emission reductions reported in the monitoring report (page 50 and 52 of the MR) i.e. 7,967.55 tCO2e (cook stoves) and 331.80 tCO2e (solar lighting) do not correspond to the calculated results reported in the emission reductions spreadsheet i.e. 8673 tCO2e and 5653 tCO2e. Kindly please rectify the errors and ensure the consistency between the monitoring report and the emission reductions calculation spreadsheet.