Submission incomplete:
Scope: The verification report does not provide an assessment on whether the calibration of measuring equipments was conducted at a frequency specified in applied monitoring methodology or EB guidance if applicable, and/or the monitoring plan (VVS v2, para 243)
Issue: The DOE (p 34) states that all the calibration certificates concluded to be compliant with the requirement and all verified calibration dates are as stated in the monitoring report. Further information is required by the DOE how it verified the calibration of meters as the reference of the verification report (p 38) indicates that it only checked the calibration certificate issued in 2010 while the monitoring period is between 19 April 2008 and 19 March 2011.
Scope: The verification report does not provide an assessment on whether the calibration of measuring equipments was conducted at a frequency specified in applied monitoring methodology or EB guidance if applicable, and/or the monitoring plan (VVS v2, para 243)
Issue: The DOE (p 34) states that all the calibration certificates concluded to be compliant with the requirement and all verified calibration dates are as stated in the monitoring report. Further information is required by the DOE how it verified the calibration of meters as the reference of the verification report (p 38) indicates that it only checked the calibration certificate issued in 2010 while the monitoring period is between 19 April 2008 and 19 March 2011.