22:31 25 Nov 24
Info Report Check
Submission incomplete:
1: Scope: The spreadsheet does not contain all parameters required to be monitored and/or reported at the intervals required by the monitoring plan and the applied methodology.
Issue: The spreadsheet submitted reports the values of the volumetric fraction of O2 in the exhaust gas of the flares, concentration of methane in the exhaust gas of the flare in dry basis at normal conditions, volumetric flow rate of the residual gas in dry basis at normal conditions and the volumetric fraction component i of the residual gas in dry basis at normal conditions on daily basis, while the monitoring plan pages 59, 60 and 61 requires to report the parameters in the hour ¨h¨.
Further, the spreadsheet submitted does not report the values of the temperature on the exhaust gas the flare, as per monitoring plan page 60.
2: Scope: The spreadsheet does not contain the formulae of calculation that are shown in the spreadsheet cells whenever possible. (EB48 - Annex 68 paragraph 10 (b) (ii)).
Issue: There is no formula for the flare efficiency in the spreadsheet submitted, the values are typed.
1: Scope: The spreadsheet does not contain all parameters required to be monitored and/or reported at the intervals required by the monitoring plan and the applied methodology.
Issue: The spreadsheet submitted reports the values of the volumetric fraction of O2 in the exhaust gas of the flares, concentration of methane in the exhaust gas of the flare in dry basis at normal conditions, volumetric flow rate of the residual gas in dry basis at normal conditions and the volumetric fraction component i of the residual gas in dry basis at normal conditions on daily basis, while the monitoring plan pages 59, 60 and 61 requires to report the parameters in the hour ¨h¨.
Further, the spreadsheet submitted does not report the values of the temperature on the exhaust gas the flare, as per monitoring plan page 60.
2: Scope: The spreadsheet does not contain the formulae of calculation that are shown in the spreadsheet cells whenever possible. (EB48 - Annex 68 paragraph 10 (b) (ii)).
Issue: There is no formula for the flare efficiency in the spreadsheet submitted, the values are typed.