Info Report Check
Submission incomplete:
1: Scope: The spreadsheet does not contain all parameters required to be monitored and/or reported at the intervals required by the monitoring plan and the applied methodology?
Issue: The spreadsheet does not contain all the parameters required by the monitoring plan and methodology: LFGflare (amount of landfill gas flared), Tflare (temperature of exhaust gas of the flare), wch4 (methane fraction in the landfill gas), T (temperature of the landfill gas), P (pressure of the landfill gas).

2: Scope: The verification report does not indicate that the information provided in the monitoring report has been cross-checked with other sources such as plant log books, inventories, purchase records, laboratory analyses. (VVM v.1.2 para 208 (a) and (b))
Issue: Regarding the monitoring and recording of Tflare (temperature of the exhaust gas of the flare) from 2 January 2008 to 7 March 2008, the verification report does not include information on how the set of data has been verified in line with VVM v 1.2 para 208 (a). Further information is required.