Info Report Check
Submission incomplete:
1: Scope: The monitoring report does not contain calculations of baseline emissions, project emissions, leakage (if any), and/or emission reductions, including reference to formulae and methods used. (EB48 - Annex 68 paragraph 10 (a) (vii))
Issue: The monitoring report / spreadsheet do not contain the calculations of PEflare, MDflared and MDelectricity.

2: Scope: The monitoring report / spreadsheet do not contain all parameters required to be monitored and/or reported at the intervals required by the monitoring plan and the applied methodology
Issue: The monitoring report / spreadsheet do not contain monitoring parameters fvCH4,FG,h (Concentration of methane in the exhaust gas of the flare), Tflare (Temperature in the exhaust gas of the flare) and Operation hours of the energy plant.