Submission incomplete:
Scope: The verification report does not state that the monitoring has been carried out in accordance with registered or the accepted revised monitoring plan. (VVS v2 para 235)
Issue: The DOE is requested to further explain how it concluded that the monitoring has been carried out in accordance with the registered monitoring plan, considering the monitoring plan requires the accuracy of 0.01 kWh for electricity meters and 0.01 Nm3 for gas flow meters, whereas the actual meters have accuracy of 0.2s (electricity meters) and 0.5 (gas flow meters).
Scope: The verification report does not state that the monitoring has been carried out in accordance with registered or the accepted revised monitoring plan. (VVS v2 para 235)
Issue: The DOE is requested to further explain how it concluded that the monitoring has been carried out in accordance with the registered monitoring plan, considering the monitoring plan requires the accuracy of 0.01 kWh for electricity meters and 0.01 Nm3 for gas flow meters, whereas the actual meters have accuracy of 0.2s (electricity meters) and 0.5 (gas flow meters).