Info Report Check
Submission incomplete:
1: Scope: The monitoring report does not contain calculations of baseline emissions, project emissions, leakage (if any), and emission reductions, including reference to formulae and methods used as per PS version 09.0 paragraph 253.
Issue: The subtotal of column C of Table 3 (the calculation process of EGy) omits the final month of monitoring, therefore the subtotal is not accurately indicated

2: Scope: The spreadsheet does not contain the formulae of calculation that are shown in the spreadsheet cells whenever possible.
Issue: The formula in Cell H42 ("ER calculation" worksheet) does not cover the full monitoring period leading to an inconsistent calculation of emission reductions in Table 2 and Table 3.

3: Scope: The verification and certification report does not provide a conclusion on the verified amount of emission reductions achieved nor/or confirm that appropriate methods and formulae for calculating baseline emissions, project emissions and leakage have been followed as per VVS version 09.0 paragraphs 403 (c) and 409 (j).
Issue: The inconsistency described above is also reflected the table in section E.8.1 of the verification report.