Info Report Check
Submission incomplete:
1: Scope: The monitoring report does not contain information on calibration of monitoring instruments (frequency, relevant dates of calibration and/or validity) as specified by the monitoring methodology and the monitoring plan. (EB48 - Annex 68 paragraph 10 (a) (iv) & EB 54 Annex 34)
Issue: According with the "Tool to determine project emissions from flaring gases containing Methane", the thermocouples used to monitor the temperature in the exhaust gas of the flare should be calibrated or replaced yearly and the Monitoring Report states that the calibration frequency is every 2-years. If the calibration is found to be delayed, guidance from EB52 - Annex 60 shall be followed.

2: Scope: The spreadsheet does not contain all parameters required to be monitored and/or reported at the intervals required by the monitoring plan and the applied methodology?
Issue: According with the "Tool to determine project emissions from flaring gases containing Methane", the project must monitor other flare operating parameters when adopting a 90% default value, however the Spreadsheet does not contain any explanation or check on whether this requirement was met.

3: Scope: The verification report does not list each parameter required by the monitoring plan (VVM v.1.2 para 206)
Issue: According with the "Tool to determine project emissions from flaring gases containing Methane", the project must monitor other flare operating parameters when adopting a 90% default value, however the Verification Report does not provide an assessment on how this parameter was verified.

4: Scope: The verification report does not provide an assessment on whether the calibration of measuring equipments was conducted at a frequency specified in applied monitoring methodology or EB guidance if applicable, and/or the monitoring plan? (VVM v.1.2 para 184 (a) (ii) & EB 52 Annex 60)
Issue: According with the "Tool to determine project emissions from flaring gases containing Methane", the thermocouples used to monitor the temperature in the exhaust gas of the flare should be calibrated or replaced yearly and the Verification Report states that the calibration frequency is every 2-years. If the calibration is found to be delayed, guidance from EB52 - Annex 60 shall be followed.