Info Report Check
Submission incomplete:
1: Scope: The verification report does not provide a conclusion on the verified amount of emission reductions achieved and/or determine that calculations of baseline emissions, project emissions and leakage as appropriate have been carried out in accordance with the formulae and methods described in the monitoring plan and the applied methodology document. (VVM v.1.2 para 208 (c) & 221 (h))
Issue: Please explain the appropriateness and conservativeness of the calculation of ST turbine (energy content of the steam supplied at the inlet of turbine), in particular, whether the enthalpy of the feed water of WHRB should be considered into the calculation.

2: Scope: The verification report does not determine if the assumptions used in emission calculations have been justified and/or emission factors, default values and other reference values have been correctly applied. (VVM v.1.2 para 208 (d) & (e))
Issue: Please justify the conservativeness of the calculation of H FWA (the enthalpy of feed water supplied to AFBC), in particular, why the maximum hourly recorded value has been used.