Submission incomplete:
The DOE shall determine whether the calibration of the measuring equipment that has an impact on the claimed GHG emission reductions or net anthropogenic GHG removals is conducted by the project participants at the frequency specified in the registered monitoring plan (paragraph 368 of VVs for PA version 2).
1) The calibration dates are not consistent between the monitoring report and the verification report. For example, the verification report (p 27-29) indicates that HPU 05976 (Main meter) & HPU05977 (Check meter) were calibrated on 03/01/2020 and 10/11/2020 and X0377326 (Main meter) & X0377327 (Check meter) were calibrated on 18/06/2019 while the monitoring report (p 22) shows that HPU 05976 (Main meter) & HPU05977 (Check meter) were calibrated on 18 June 2019 and X0377326 (Main meter) & X0377327 (Check meter) were calibrated on 3 January 2020.

2) The verification report (p 27-28) shows that X0377326 (Main meter) & X0377327 (Check meter) were installed on 01/01/2019 and removed on 11/11/2020 with the calibration record on 18/06/2019. However, the DOE did not provide information on how it verified the calibration of the meters between 1 April 2019 and 17 June 2019 considering that the monitoring period is 01 Apr 19 - 31 Dec 20.