Info Report Check
Submission incomplete:
1: Scope: The monitoring report does not contain the values of the monitored parameters. (EB 54 Annex 34)
Issue: The monitoring report does not provide the values of:
- Oxygen and methane concentration in exhaust gas; and
- Average technical transmission and distribution losses in the grid.

2: Scope: The monitoring report does not contain calculations of baseline emissions, project emissions, leakage (if any), and/or emission reductions, including reference to formulae and methods used. (EB48 - Annex 68 paragraph 10 (a) (vii))
Issue: The calculation of emissions from flaring (including the estimation of flare efficiency) are not presented.

3: Scope: The spreadsheet does not contain all parameters required to be monitored and/or reported at the intervals required by the monitoring plan and the applied methodology?
Issue:The calculation of emissions from flaring (including the estimation of flare efficiency) are not presented.

4: Scope: The verification report does not list each parameter required by the monitoring plan (VVM v.1.2 para 206)
Issue: See issue above (paragraph 1.6 of checklist)