Submission incomplete:
Scope: The verification and certification report does not determine if the assumptions used in emission calculations have been justified as per VVS version 09.0 paragraph 403 (d).
Issue: The DOE is requested to substantiate how it has verified that the application of the parameter TDLk (transmission loss of baseline electricity consumption), equal to 20% as per ER sheet "MR11 summarized-LLC-V.3" "Calculation", cell "E12" and "E59 – E62" is in accordance with the paragraph 53 of the applied methodology and “Tool to calculate baseline, project and/or leakage emissions from electricity consumption”, version 01. It is to be noted that paragraph 53 of the applied methodology and the tool states “Use as default values of 3% for baseline electricity consumption sources” or “Use as default values of 20% for baseline electricity consumption sources if the electricity consumption by all project and leakage electricity consumption sources to which scenario A or scenario C (cases C.I or C.III) applies is larger than the electricity consumption of all baseline electricity consumption sources to which scenario A or scenario C (cases C.I or C.III) applies”.