VVS-PA Para 368
As per page 19 of the verification report, DOE has mentioned that the error for meters with delayed calibration was found to be within the permissible limits. However, for main meter KAB 11082, the calibration due date was 05/09/2016 and no calibration was carried out after this date. DOE is therefore requested to clarify how it confirmed that the error for the meter was within permissible limits between 06/09/2016 and 31/12/2016. Refer Para 368 of VVS-PA, version 3.0.