Submission incomplete:
Scope: The verification report does not provide an assessment on whether the calibration of measuring equipments was conducted at a frequency specified in applied monitoring methodology or EB guidance if applicable, and/or the monitoring plan? (VVM v.1.2 para 184 (a) (ii) & EB 52 Annex 60)
Issue: The methodology (AM0001 v05.2 on page 16 requires all of the measurement instruments are to be recalibrated "monthly" per internationally accepted procedures except for the HFC 23 flow meters whose recalibration frequency is six months with a zero check being conducted weekly to reduce the error level. The DOE must report the dates on which each of the equipment measuring the required parameters was re-calibrated as per internationally accepted procedures except for the HFC23 flow meters. In case of any delayed calibration, the DOE must provide information on the compliance with EB52 Annex 60.