Info Report Check
Submission incomplete:
1: Scope: The monitoring report does not contain the values of the monitored parameters. (EB 54 Annex 34)
Issue: The monitoring report does not provide the dates and results of the flare efficiency monitoring. It also does not explain whether the flare was operated according with the manufacturer’s recommendations, according with the monitoring methodology in case of enclosed flares.

2: Scope: The verification report does not list each parameter required by the monitoring plan or monitoring methodology (VVM v.1.2 para 206)
Issue: The Verification Report does not provide the dates and results of the flare efficiency monitoring. It also does not explain how the DOE verified that the flare was operated according with the manufacturer’s recommendations, according with the monitoring methodology in case of enclosed flares.