Submission incomplete:
Scope: The verification report does not provide an assessment of the compliance with EB 52 Annex 60 'Guidelines for assessing compliance with the calibration frequency requirements' for the calibration delay. (VVM v.1.2 para 184 (a) (ii) & EB 52 Annex 60)
Issue: The DOE is requested to clarify how the calibration frequency for the parameter Qy,ww, to be performed every 2 years as per the revised monitoring plan has been assessed, as the latest calibration reported was performed on 18/09/2007.