Submission incomplete:
Scope: The verification report does not provide an assessment on whether the calibration of measuring equipments was conducted at a frequency specified in applied monitoring methodology or EB guidance if applicable, and/or the monitoring plan? (VVM v.1.2 para 184 (a) (ii) & EB 52 Annex 60)
Issue:
The DOE has only included in the VR the verification of the calibration certificates on 25/02/2011 and 02/08/2011 for both meters (Revenue Meter and Cross-Check Meter). Taking into account that the current monitoring period is from 21/12/2010 to 25/12/2011. The DOE is requested to clarify how it was verified the calibration validity of the Revenue and Cross-Check Meters during the period from 22/12/2010 to 24/02/2011.