Info Report Check
Submission incomplete:
1: Scope: The monitoring report does not contain calculations of baseline emissions, project emissions, leakage (if any), and/or emission reductions, including reference to formulae and methods used. (EB48 - Annex 68 paragraph 10 (a) (vii))
Issue:
The monitoring report states page 28 that Caprolactam production was behind the permitted range. In this case (case 1), the baseline does not have to be recalculated. However it is also stated on the same page that "therefore, the baseline is recalculated". The project participant is requested to clarify this inconsistency.

2: Scope: The spreadsheet does not contain all parameters required to be monitored and/or reported at the intervals required by the monitoring plan and the applied methodology?
Issue:
The spreadsheet provided does not contain the parameters related to the version 9 of the monitoring report. The project participant is requested to provide a spreadsheet corresponding to the version 9 of the monitoring report.

3: Scope: The verification report does not provide a conclusion on the verified amount of emission reductions achieved and/or determine that calculations of baseline emissions, project emissions and leakage as appropriate have been carried out in accordance with the formulae and methods described in the monitoring plan and the applied methodology document. (VVM v.1.2 para 208 (c) & 221 (h))
Issue:
The monitoring report (page 28) states that the baseline has to be recalculated. However the formulae provided (page A-52) of the verification report for the baseline emission calculation does not include the correction factor. The DOE is requested to clarify this inconsistency.