Info Report Check
Submission incomplete:
Scope: The verification and certification report does not list each parameter required by the monitoring plan and does not provide an statement on how the DOE verified the information flow for these parameters including the values in the monitoring reports as per VVS version 09.0 paragraphs 393 and 409 (e).
Issue: As per the registered PDD page 61, "for the dispatch data analysis OM, the year in which the project activity displaces grid electricity and the emission factor updating annually during monitoring is utilized". In page 51 of verification report, it has been noted that "The selected 2016 vintage value for the monitoring parameter EFgrid,OM,y = EFgrid,OM-DD,y (0.6228tCO2/MWh) was
confirmed by the EPIC verification to correctly represent the value for EFgrid,OM,y = EFgrid,OM-DD,y for year 2016 as officially published by the DNA of Brazil". The DOE is requested to substantiate how it has verified that the operating margin CO2 emission factor is correctly applied for this monitoring period, i.e. 01/01/2017-30/04/2017 as per the PDD.