Submission incomplete:
1: Scope: The monitoring report does not contain the values of the monitored parameters. (EB 54 Annex 34)
Issue: It is not clear how the compliance to manufacturer’s specification for operation of flare, especially the flare temperature is met. As per flare manufacturer’s specifications mentioned in Annex 5 of registered PDD, the combustion temperature at flare should be between 1,000 – 1,200 0C. It is not evident from either monitoring report or verification report if the combustion temperature at flare is measured. Details of thermo couple (serial number, model, accuracy, calibration dates) to measure combustion temperature at flare are not available in the monitoring report.
Also, the data on flare temperature and flare exhaust gas temperature is not mentioned in the monitoring report.
2: Scope: The spreadsheet does not contain all parameters required to be monitored and/or reported at the intervals required by the monitoring plan and the applied methodology?
Issue: The data on flare temperature (compliance to manufacturer’s specifications) and flare exhaust gas temperature is not mentioned in the spreadsheet.
3: Scope: The spreadsheet does not contain the formulae of calculation that are shown in the spreadsheet cells whenever possible. (EB48 - Annex 68 paragraph 10 (b) (ii)).
Issue: The formula for calculation of baseline emissions from destruction of methane in flare and project emission from flare are not available in the excel spread sheets.
4: Scope: The verification report does not indicate that the information provided in the monitoring report has been cross-checked with other sources such as plant log books, inventories, purchase records, laboratory analyses. (VVM v.1.2 para 208 (a) and (b))
Issue: It is not clear how the DOE has checked the compliance to manufacturer’s specification for operation of flare, especially the flare temperature. As per flare manufacturer’s specifications mentioned in Annex 5 of registered PDD, the combustion temperature at flare should be between 1,000 – 1,200 0C. It is not evident from either monitoring report or verification report if the combustion temperature at flare is measured.
1: Scope: The monitoring report does not contain the values of the monitored parameters. (EB 54 Annex 34)
Issue: It is not clear how the compliance to manufacturer’s specification for operation of flare, especially the flare temperature is met. As per flare manufacturer’s specifications mentioned in Annex 5 of registered PDD, the combustion temperature at flare should be between 1,000 – 1,200 0C. It is not evident from either monitoring report or verification report if the combustion temperature at flare is measured. Details of thermo couple (serial number, model, accuracy, calibration dates) to measure combustion temperature at flare are not available in the monitoring report.
Also, the data on flare temperature and flare exhaust gas temperature is not mentioned in the monitoring report.
2: Scope: The spreadsheet does not contain all parameters required to be monitored and/or reported at the intervals required by the monitoring plan and the applied methodology?
Issue: The data on flare temperature (compliance to manufacturer’s specifications) and flare exhaust gas temperature is not mentioned in the spreadsheet.
3: Scope: The spreadsheet does not contain the formulae of calculation that are shown in the spreadsheet cells whenever possible. (EB48 - Annex 68 paragraph 10 (b) (ii)).
Issue: The formula for calculation of baseline emissions from destruction of methane in flare and project emission from flare are not available in the excel spread sheets.
4: Scope: The verification report does not indicate that the information provided in the monitoring report has been cross-checked with other sources such as plant log books, inventories, purchase records, laboratory analyses. (VVM v.1.2 para 208 (a) and (b))
Issue: It is not clear how the DOE has checked the compliance to manufacturer’s specification for operation of flare, especially the flare temperature. As per flare manufacturer’s specifications mentioned in Annex 5 of registered PDD, the combustion temperature at flare should be between 1,000 – 1,200 0C. It is not evident from either monitoring report or verification report if the combustion temperature at flare is measured.