22:33 27 Dec 24
Info Report Check
Submission incomplete:
The DOE is requested to clarify how it has complied with the CDM Validation and Verification Standard for Project Activities, version 03.0, paragraph 371. In particular, the DOE is requested to explain how it has determined that the calibration of certain measuring equipment that has an impact on the claimed GHG emission reductions, namely the Annubar geothermal flow meters, the Mettler Toledo Analyzer/Titrimeter, and the Gas chromatographer, are conducted at the frequency specified in the applied methodologies and/or the registered monitoring plan, considering the information provided in the Monitoring Report and in the Verification and Certification Report on the frequency of calibration and dates when calibration was performed for each of these equipment.
The DOE is requested to clarify how it has complied with the CDM Validation and Verification Standard for Project Activities, version 03.0, paragraph 371. In particular, the DOE is requested to explain how it has determined that the calibration of certain measuring equipment that has an impact on the claimed GHG emission reductions, namely the Annubar geothermal flow meters, the Mettler Toledo Analyzer/Titrimeter, and the Gas chromatographer, are conducted at the frequency specified in the applied methodologies and/or the registered monitoring plan, considering the information provided in the Monitoring Report and in the Verification and Certification Report on the frequency of calibration and dates when calibration was performed for each of these equipment.
Offset now: visit the United Nations Carbon Offset Platform
Connect with us: