09:19 20 Jan 25
Info Report Check
Submission incomplete:
1: The DOE is requested to:
1) Provide a detailed project diagram replacing the one on page 9 of the MR v6. This diagram shall show each of the 5 back-up boilers (capacity of 17.2 MW), and the new 45.466 MW boiler(s) and their corresponding turbines. In doing so, please indicate:
a. all the boilers with the details of their capacities,
b. which boilers are in operation,
c. and which boilers are C4, C5, C6 (as indicated on the ER spreadsheet, tab “Energy Report 2018”).
2) Clarify the discrepancy in the number of turbines as per MR v6 page 2 (3 turbines) in contrast with the diagram on MR v6 page 3 (5 turbines, g1 to g5), which correspond to the 17.2 MW of capacity.
2: The DOE is requested to:
1) Provide traceable formulas for the calculation of “Steam produced in boilers” (ER spreadsheet, tabs: Energy Report 2018, Energy Report 2018-2019, Energy Report 2019-2020 and Energy Report 2020; e.g.: tonnes steam/hour, columns W-AA in Energy Report 2018). In doing so, please explain how the total amount of steam produced in all the boilers is calculated. Please consider that e.g. cell Z6 of the Energy Report 2018 sheet shows a total of 2791.73 tonnes/h for 1-Jan-18, and the quantity of steam produced in boiler C5 is 345 tonnes/h (cell X6). Therefore, please clarify where the rest of the steam comes from (C4: 0 tonnes/h and C5: 0 tonnes/h) by including the respective traceable formulas. This shall be applied to all Energy Report sheets (2018, 2018-2019, 2019-2020, 2020).
2) Include the formulae for the ratio of the amount of steam produced per amount of bagasse burned (tonnes of steam/tonnes of bagasse). The values referred to are in cells AB3, AC3, AD3, AE3, AF3 of the tab Energy Report 2018. The DOE shall address the same issue for Energy Report 2018-2019, Energy Report 2019-2020 and Energy Report 2020. In doing so, the DOE shall further verify such ratios.
3) Clarify how the “Baseline emissions due to disposal of biomass residues in year y (t CO2e)” (BEBR,y) shown in C14, D14 and E14, sheet 'BL Step 6 Results BL', were calculated. Please provide the corresponding formula, as per page 44 of the ACM0006 / Version 12.1.1. In doing so, the DOE shall further verify the calculations of the biomass residues.
4) Make sure that all the calculations shown in the spreadsheet can be traceable and the application of the formulae are explained and verified.
1: The DOE is requested to:
1) Provide a detailed project diagram replacing the one on page 9 of the MR v6. This diagram shall show each of the 5 back-up boilers (capacity of 17.2 MW), and the new 45.466 MW boiler(s) and their corresponding turbines. In doing so, please indicate:
a. all the boilers with the details of their capacities,
b. which boilers are in operation,
c. and which boilers are C4, C5, C6 (as indicated on the ER spreadsheet, tab “Energy Report 2018”).
2) Clarify the discrepancy in the number of turbines as per MR v6 page 2 (3 turbines) in contrast with the diagram on MR v6 page 3 (5 turbines, g1 to g5), which correspond to the 17.2 MW of capacity.
2: The DOE is requested to:
1) Provide traceable formulas for the calculation of “Steam produced in boilers” (ER spreadsheet, tabs: Energy Report 2018, Energy Report 2018-2019, Energy Report 2019-2020 and Energy Report 2020; e.g.: tonnes steam/hour, columns W-AA in Energy Report 2018). In doing so, please explain how the total amount of steam produced in all the boilers is calculated. Please consider that e.g. cell Z6 of the Energy Report 2018 sheet shows a total of 2791.73 tonnes/h for 1-Jan-18, and the quantity of steam produced in boiler C5 is 345 tonnes/h (cell X6). Therefore, please clarify where the rest of the steam comes from (C4: 0 tonnes/h and C5: 0 tonnes/h) by including the respective traceable formulas. This shall be applied to all Energy Report sheets (2018, 2018-2019, 2019-2020, 2020).
2) Include the formulae for the ratio of the amount of steam produced per amount of bagasse burned (tonnes of steam/tonnes of bagasse). The values referred to are in cells AB3, AC3, AD3, AE3, AF3 of the tab Energy Report 2018. The DOE shall address the same issue for Energy Report 2018-2019, Energy Report 2019-2020 and Energy Report 2020. In doing so, the DOE shall further verify such ratios.
3) Clarify how the “Baseline emissions due to disposal of biomass residues in year y (t CO2e)” (BEBR,y) shown in C14, D14 and E14, sheet 'BL Step 6 Results BL', were calculated. Please provide the corresponding formula, as per page 44 of the ACM0006 / Version 12.1.1. In doing so, the DOE shall further verify the calculations of the biomass residues.
4) Make sure that all the calculations shown in the spreadsheet can be traceable and the application of the formulae are explained and verified.
Offset now: visit the United Nations Carbon Offset Platform