Submission incomplete:
1: Scope: The verification report does not indicate that the information provided in the monitoring report has been cross-checked with other sources such as plant log books, inventories, purchase records, laboratory analyses. (VVM v.1.2 para 208 (a) and (b))
Issue: It is not clear how the imported electricity has been cross-checked with the invoices, in particular, why the value of the invoice (261.13 MWh) is 253% higher than the results measured by the main meter (73.92 MWh).

2: Scope: The verification report does not provide an assessment on whether the calibration of measuring equipments was conducted at a frequency specified in applied monitoring methodology or EB guidance if applicable, and/or the monitoring plan? (VVM v.1.2 para 184 (a) (ii) & EB 52 Annex 60)
Issue: It is not clear whether the calibration frequency is in line with the industry standards as per the monitoring plan. Please also specify the requirement of the calibration frequency, the valid period of the calibrations of each meter.