Submission incomplete:
1: Scope: The verification report does not indicate that the information provided in the monitoring report has been cross-checked with other sources such as plant log books, inventories, purchase records, laboratory analyses. (VVM v.1.2 para 208 (a) and (b))
Issue: The amount of bagasse consumed in the project activity is calculated based on amount of steam used in project turbine (G3) and the project boiler efficiency. The project boiler efficiency is calculated based on total steam generated for G3 and G4 turbines with total quantity of bagasse consumed in boilers. The DOE has not stated in the verification report how the monitored steam flow data has been verified and cross-checked.
2: Scope: The verification report does not provide a conclusion on the verified amount of emission reductions achieved and/or determine that calculations of baseline emissions, project emissions and leakage as appropriate have been carried out in accordance with the formulae and methods described in the monitoring plan and the applied methodology document. (VVM v.1.2 para 208 (c) & 221 (h))
Issue: The amount of bagasse consumed in the project activity is calculated based on amount of steam used in project turbine (G3) and the project boiler efficiency. The project boiler efficiency is calculated based on total steam generated for G3 and G4 turbines with total quantity of bagasse consumed in boilers. The DOE has not provided a verification opinion in the verification report on this calculation.
3: Scope: The verification report does not provide an assessment on whether the calibration of measuring equipments was conducted at a frequency specified in applied monitoring methodology or EB guidance if applicable, and/or the monitoring plan? (VVM v.1.2 para 184 (a) (ii) & EB 52 Annex 60)
Issue: The DOE has not provided in the verification report an assessment of the calibration of steam flow meters.
1: Scope: The verification report does not indicate that the information provided in the monitoring report has been cross-checked with other sources such as plant log books, inventories, purchase records, laboratory analyses. (VVM v.1.2 para 208 (a) and (b))
Issue: The amount of bagasse consumed in the project activity is calculated based on amount of steam used in project turbine (G3) and the project boiler efficiency. The project boiler efficiency is calculated based on total steam generated for G3 and G4 turbines with total quantity of bagasse consumed in boilers. The DOE has not stated in the verification report how the monitored steam flow data has been verified and cross-checked.
2: Scope: The verification report does not provide a conclusion on the verified amount of emission reductions achieved and/or determine that calculations of baseline emissions, project emissions and leakage as appropriate have been carried out in accordance with the formulae and methods described in the monitoring plan and the applied methodology document. (VVM v.1.2 para 208 (c) & 221 (h))
Issue: The amount of bagasse consumed in the project activity is calculated based on amount of steam used in project turbine (G3) and the project boiler efficiency. The project boiler efficiency is calculated based on total steam generated for G3 and G4 turbines with total quantity of bagasse consumed in boilers. The DOE has not provided a verification opinion in the verification report on this calculation.
3: Scope: The verification report does not provide an assessment on whether the calibration of measuring equipments was conducted at a frequency specified in applied monitoring methodology or EB guidance if applicable, and/or the monitoring plan? (VVM v.1.2 para 184 (a) (ii) & EB 52 Annex 60)
Issue: The DOE has not provided in the verification report an assessment of the calibration of steam flow meters.