The VVS-PA ver. 02 paragraph 369 requires that:
If, during the verification of a certain monitoring period, the DOE identifies that the calibration has been delayed and the calibration has been implemented after the monitoring period in consideration (i.e. the results of delayed calibration are available), referring to the illustrative examples in the appendix below, the DOE may conclude its verification, provided the following conservative approach is adopted in the calculation of GHG emission reductions or net anthropogenic GHG removals:
(a) Applying the maximum permissible error of the instrument to the measured values taken during the period between the scheduled date of calibration and the actual date of calibration, if the results of the delayed calibration do not show any errors in the measuring equipment, or if the error is smaller than the maximum permissible error; or
(b) Applying the error identified in the delayed calibration test, if the error is beyond the maximum permissible error of the measuring equipment.

The DOE (VR page 13) has verified that there was a calibration delay for the main/check meters for Line 1 and Line 2 and thus the maximum error factor (0.2%) was applied. The DOE shall provide information on it verified the results of delayed calibration in order to justify the application of the maximum permissible error factor 0.2% (please refer to VVS-PA ver. 02 paragraph 369).