Submission incomplete:
Scope: The verification report does not provide an assessment of the compliance with EB 52 Annex 60 'Guidelines for assessing compliance with the calibration frequency requirements' for the calibration delay. (VVM v.1.2 para 184 (a) (ii) & EB 52 Annex 60)
Issue:
The DOE is requested to provide further information on how it has verified the results of the delayed calibration test, in order to demonstrate that those errors in the measuring equipment are not higher than the maximum permissible error (0.2%) of the installed meters as per EB52 Annex 60 paragraph 4 a) b)