Submission incomplete:
1: Scope: The monitoring report does not contain information on calibration of monitoring instruments (frequency, relevant dates of calibration and/or validity) as specified by the monitoring methodology and the monitoring plan. (EB48 - Annex 68 paragraph 10 (a) (iv) & EB 54 Annex 34)
Issue: There is no information on the calibration of equipments used to monitor the following parameters:
M11 Percentage of methane in the biogas at biodigester outlet,
M15 Fraction of time gas is combusted in the flare;
B2: Flow rate of raw effluent at digester inlet.

The PP shall provide more information about calibration dates and describe whether the calibration of equipments covers the monitoring period 03/06/2003-30/06/2008.

2: Scope: The verification report does not provide an assessment of the compliance with EB 52 Annex 60 'Guidelines for assessing compliance with the calibration frequency requirements' for the calibration delay. (VVM v.1.2 para 184 (a) (ii) & EB 52 Annex 60)
Issue:
There is no information on the calibration of equipments used to monitor the following parameters:
M11 Percentage of methane in the biogas at biodigester outlet,
M15 Fraction of time gas is combusted in the flare;
B2: Flow rate of raw effluent at digester inlet.

The DOE shall provide more information about the verification of calibration dates to verify whether the calibration of equipments covers the monitoring period 03/06/2003-30/06/2008 and whether there is calibration delay