Submission incomplete:
Scope: The verification report does not provide an assessment of the compliance with EB 52 Annex 60 'Guidelines for assessing compliance with the calibration frequency requirements' for the calibration delay. (VVM v.1.2 para 184 (a) (ii) & EB 52 Annex 60)
Issue:
The DOE has checked the monitoring equipment and calibration records of the meters and it was found that there was delay in calibration in some of the monitoring equipment for the current monitoring period. The DOE explains that the maximum correction factor has been applied for the monitoring parameters for delay in calibration in the emission reduction calculation. It is mentioned that this procedure is in line with the “General guidelines to SSC methodologies” and “Guidelines for assessing compliance with the calibration frequency requirement”.

However, it is not clear how the DOE has verified the appropriateness of the maximum correction factor applied for each delayed measured value. It is since: (i) the DOE has verified that the PDD does not specify the accuracy of the monitoring equipment, (ii) the DOE does not provide details about the verification of error identified during delayed calibration, and (iii) the DOE has simply mentioned that the monitoring equipment represent "good monitoring practise" and provide accuracies for the monitoring equipment.

Please provide details about how the DOE has verified that the maximum permissible error of all the measuring instruments are specified by the respective manufacturers as their technical specification, as per the EB 52 Annex 60 'Guidelines for assessing compliance with the calibration frequency requirements'. In doing so, please include the corrections applied to the delayed measured values in the emission reduction spreadsheet.