19:41 06 May 25
Info Report Check
Submission incomplete:
1: How the value of parameter CODremoved,PJ,k,y (i.e. 0.063937 t/m3, the chemical oxygen demand removed by the treatment system) is derived is not traceable in the ER sheet (column E in tab “Input values”). In addition, it is noted that these values applied in calculating the project emission are not matching values calculated as per methodology requirement (i.e. difference between the inflow COD and the outflow COD). Please refer to footnote 10 of AMS III.H version 16.
2: The formula to calculate PEflaring,y (project emissions due to incomplete flaring) in page 23 of the monitoring report does not result in the reported value (i.e. 5817.53 tCO2e).
1: How the value of parameter CODremoved,PJ,k,y (i.e. 0.063937 t/m3, the chemical oxygen demand removed by the treatment system) is derived is not traceable in the ER sheet (column E in tab “Input values”). In addition, it is noted that these values applied in calculating the project emission are not matching values calculated as per methodology requirement (i.e. difference between the inflow COD and the outflow COD). Please refer to footnote 10 of AMS III.H version 16.
2: The formula to calculate PEflaring,y (project emissions due to incomplete flaring) in page 23 of the monitoring report does not result in the reported value (i.e. 5817.53 tCO2e).