Info Report Check
Submission incomplete:
1: Scope: The verification report does not provide an assessment on whether the calibration of measuring equipments was conducted at a frequency specified in applied monitoring methodology or EB guidance if applicable, and/or the monitoring plan (VVS v2, para 243)
Issue: The Verification Report and the Monitoring Report do not provide information of the calibration of the moisture meter.

2: Scope: The verification report does not provide a conclusion on the verified amount of emission reductions achieved and/or determine that calculations of baseline emissions, project emissions and leakage as appropriate have been carried out in accordance with the formulae and methods described in the monitoring plan and the applied methodology document. (VVS v2, para 246 (c), 284 (i))
Issue: The calculation of the leakage in the spreadsheet considers a figure of 0.01172024. Please explain what the figure is.


3: Scope: The verification report does not determine if the assumptions used in emission calculations have been justified and/or emission factors, default values and other reference values have been correctly applied. (VVS v2, para 246 (d))
Issue: The DOE is requested to explain how it verified the diesel being the most carbon intensive fuel in the country based on the Energy Balance 2004 and the emission factor calculation worksheet, considering: (i) the publicly available information about the Energy Balance 2004 of Sri Lanka shows that there is also coal used in the country; (ii) the emission factor calculation may only contain information of the fuel of power plants.