Info Report Check
Submission incomplete:
Scope: The monitoring report does not contain a description of the monitoring systems, quality assurance and/or quality control system employed by the project activity, data collection procedures (information flow including data generation, aggregation, recording, calculation and reporting), organizational structure, roles and responsibilities of personnel, emergency procedures for the monitoring system, and/or line diagrams showing all relevant monitoring points). (EB48 - Annex 68 paragraph 10 (a) (ii) & EB 54 Annex 34).
Issue: The PP/DOE are requested to provide the detailed reasons for the estimated SF6 inventory decreases following the template outlined in the in the monitoring plan (Annex 4 of the registered PDD) and required by the methodology (Table on page 9).