Submission incomplete:
1: Scope: The monitoring report does not contain information on calibration of monitoring instruments (frequency, relevant dates of calibration and/or validity) as specified by the monitoring methodology and the monitoring plan. (EB48 - Annex 68 paragraph 10 (a) (iv) & EB 54 Annex 34)
Issue: The PP is required to provide further information about the calibration of the meters for measuring the operating hours (e.g. date of calibration and validity) as the monitoring report does not include this information.
2: Scope: The verification report does not provide an assessment on whether the calibration of measuring equipments was conducted at a frequency specified in applied monitoring methodology or EB guidance if applicable, and/or the monitoring plan? (VVM v.1.2 para 184 (a) (ii) & EB 52 Annex 60)
Issue:The DOE is requested to justify how the test report for time accuracy dated 27-02-2008 is valid for this monitoring period (17/07/2009 - 30/10/2011) as the register monitoring plan requires a calibration of meters within 3 years (PDD v.2.1 page 49)
1: Scope: The monitoring report does not contain information on calibration of monitoring instruments (frequency, relevant dates of calibration and/or validity) as specified by the monitoring methodology and the monitoring plan. (EB48 - Annex 68 paragraph 10 (a) (iv) & EB 54 Annex 34)
Issue: The PP is required to provide further information about the calibration of the meters for measuring the operating hours (e.g. date of calibration and validity) as the monitoring report does not include this information.
2: Scope: The verification report does not provide an assessment on whether the calibration of measuring equipments was conducted at a frequency specified in applied monitoring methodology or EB guidance if applicable, and/or the monitoring plan? (VVM v.1.2 para 184 (a) (ii) & EB 52 Annex 60)
Issue:The DOE is requested to justify how the test report for time accuracy dated 27-02-2008 is valid for this monitoring period (17/07/2009 - 30/10/2011) as the register monitoring plan requires a calibration of meters within 3 years (PDD v.2.1 page 49)