Scope: The verification report does not contain information on all CARs, CLs and FARs and/or provide an assessment and close out of any CARs, CLs or FARs issued. (VVM v.1.2 para 192, 194)
Issue:"The DOE (p. 8) states that "during the site visit it was observed that a meter (serial number IP6H48) was installed inside the power house. Meter IP6H48 is mono directional and it is used for measuring the electricity imported from a 13.8 kV OHTL. However, the monitoring plan of the registered PDD does not include the electricity import from the 13.8 kV. Further information is required by the DOE on why it did not raise a FAR to revise the monitoring plan to include the monitoring of the electricity import as the monitoring of this parameter is required to confirm para 77 of VVM". It is observed that the same issue was raised during the previous submission (10/ 09/2012) and it was clarified during the Direct Communication held on 03/12/2012. Even so, the issue was not addressed.