Info Report Check
Submission incomplete:
Scope: The verification and certification report does not provide a conclusion on the verified amount of emission reductions achieved nor/or confirm that appropriate methods and formulae for calculating baseline emissions, project emissions and leakage have been followed as per VVS version 09.0 paragraphs 403 (c) and 409 (j).
Issue: Page 30 of the revised and approved PDD (v.6) has required to apply both factors 0.9979 and 1.0021 respectively to calculate EGout and EGin due to the propagation of meter errors (M5 and M6). However the VR does not provide information to clarify:
(1) Why the CER calculation provided in the MR does not apply both factors to calculate EGout and EGin as per the revised and approved PDD (v.6).
(2) How both factors 0.9979 and 1.0021 could be still applicable to the project activity, given that the revised and approved PDD (v.6) states that accuracy of M5 and M6 is 0.5, however now the MR page 8 shows that accuracy of M5, new M5 and M6 is 0.2.