Submission incomplete:
Scope: The monitoring report does not contain information on calibration of monitoring instruments (frequency, relevant dates of calibration and/or validity) as specified by the monitoring methodology and the monitoring plan. (EB48 - Annex 68 paragraph 10 (a) (iv) & EB 54 Annex 34)
Issue: Regarding the calibration of the equipment used to measure the temperature and pressure of the biogas, the Monitoring Plan (page 40) states that the calibrations will be performed according to the manufacturer´s specifications. However, there is no information on the calibration of the instruments used to measure the temperature of the biogas entering the biogas engine 1, 2, 3 and the flare and on the instruments to measure the pressure of the biogas entering the biogas engine 1, 2 and 3 (i.e., TI61, TI62, TI63, TI64, PI61, PI62 and PI63 as per page 7 of the monitoring report) . The Verification Report (Section 3.3), states that these instruments are used to convert the biogas flows from m3 to Nm3.