Review Request Form
Submitted Request for Review Form (Version 03.0)
SECTION 1: GENERAL INFORMATION
Title and UNFCCC reference number
of the project activity or
programme of activities (PoA)
5368: "Wampu Hydro Electric Power Project"
SECTION 2: BASIS FOR REVIEW REQUEST
Please indicate the relevant requirement(s) for which you have reasonable concern about whether the project activity or PoA complies,
by checking the appropriate box and specifying the relevant requirement(s) in the list below.

SECTION 3: COMMENTS SUPPORTING REVIEW REQUEST
Please elaborate the reason for requesting a review on the issues you indicated in section 2 above

1) Refer to paragraph: VVS-PA ver. 02 paragraph 404(b), Tool07 ver. 07 paragraph 42(a),

As per the PDD, average Operating Margin with ex-ante option is used for the second crediting period. Paragraph 42 (a) of the applicable Tool07 “Tool to calculate the emission factor for an electricity system, ver. 07” requires using a 3-year generation-weighted average, based on the most recent data available at the time of submission of the CDM-PDD to the DOE for validation. However, the EF spreadsheet (workbook “Ex-Ante”, cell E37) indicates that the average Operating Margin is calculated as a simple average, whereas the Tool requires this to be generation-weighted average. The DOE is requested to further substantiate how it validated the calculation of the operating margin (OM) in compliance with Tool07.