Scope: The verification report does not provide an assessment on whether the calibration of measuring equipments was conducted at a frequency specified in applied monitoring methodology or EB guidance if applicable, and/or the monitoring plan (VVS v2, para 243)
Issue: The DOE states that the installed equipment essential for measuring parameters required for calculating emission reductions are calibrated appropriately (page 29) and reviewed the calibration certificates dated 08/06/2009 and 20/07/2011. The PP has applied a 2% discount for the generation between 15/06/2011 to 20/07/2011, however the DOE did not provide information regarding the calibration delay and whether the delayed calibration report meets the requirements of the Guidelines for assessing compliance with the calibration frequency requirements, EB 52, Annex 60.